GENERATOR DIESEL TECNICS

Serie T

New product

Generators Grupos electrógenos de la serie TKF y TYD series, equipped with an TECNICS engine of 1500 RPM and a frequency of 50 Hz, has a power range which comprises of 12 to 550 Kva, cooled by water.

Available in the following versions:

  • Open
  • Soundproof

Models available with Diesel engine.

More details

Add to wishlist

Data sheet

TRADEMARKTECNICS
RPM1500
POWER ( KVA )12 a 308
HZ50
VOLTAJE400 / 230
COOLING SYSTEMWATER

More info

MORE INFORMATION


Generator recommended for situations where there is no mains power or as backup or safety equipment when cutting and / or power failures occur.

The mobile elements, distribution belt, fan, etc., and those parts which during operation acquire high temperatures, exhaust manifold, etc, include their corresponding protections, in compliance with the requirements of Machinery Safety Directive 2006/42.

SERIES MODELS


SERIES

ENGINEPOWER (KVA)DIMENSIONS (MM)
( LENGTH x WIDTH x HEIGHT )
REF.TRADEMARKMODELESPPRPHZR.P.MVOLTAGEOPEN
SOUNDPROOF
TKF40ETECNICS KFN4105ZD4036501500400/2301830 x 750 x 1700

2380 x 970 x 1430
TKF75ETECNICS KFR4105ZLD7567501500400/2302100 x 750 x 1800

2380 x 970 x 1430
TKF90ETECNICS KFR4110ZLD9080501500400/2302000 x 750 x 1700

3000 x 1030 x 1675
TKF110ETECNICS KFR6105ZLD110100501500400/2302500 x 810 x 1860

3000 x 1030 x 1675
TKF150ETECNICS KFR6105BZLD150130501500400/2302550 x 900 x 2060

3380 x 1130 x 2000
TKF165ETECNICS KFR6110BZLD165150501500400/2302550 x 900 x 2060

3380 x 1130 x 2000
TKF187ETECNICS KFR6110ZLD187165501500400/2302500 x 900 x 2060

3380 x 1130 x 2000
TKF250ETECNICS KF6126-42D250225501500400/2303060 x 850 x 2100

3380 x 1130 x 2000
TKF308ETECNICS KFSTD12D-308308275501500400/2303880 x 1400 x 2000

3110 x 850 x 2140

SERIE TYD

ENGINEPOWER (KVA)DIMENSIONS (MM)
( LENGTH x WIDTH x HEIGHT )
REF.TRADEMARKMODELESPPRPHZR.P.MVOLTAGEOPEN
SOUNDPROOF
TYD12ETECNICS YD385D1210.8501500400/2301500 X 630 X 1200
1800 X 835 X 1010
TYD15ETECNICS YD385D1513.5501500400/2301500 X 630 X 1200
1800 X 835 X 1010
TYD20ETECNICS YD385D2018501500400/2301500 X 630 X 1200
1800 X 835 X 1010
TYD25ETECNICS YDY490D2522501500400/2301500 X 630 X 1350
1900 X 835 X 1010
TYD28ETECNICS YDY495D2825501500400/2301500 X 630 X 1350
1900 X 835 X 1010
TYD30ETECNICS YD4102D3027501500400/2301500 X 630 X 1350
2000 X 840 X 1130
TYD35ETECNICS YDY4102D3531501500400/2301500 X 630 X 1350
2000 X 840 X 1130
TYD50ETECNICS YDY4105ZLD5045501500400/2301830 x 750 x 1700

2380 x 970 x 1430
TYD60ETECNICS YDY4105ZLD6054501500400/2301830 x 750 x 1700

2380 x 970 x 1430

OPTIONS


Protección del grupo electrógeno. Magnetotérmico.

PROTECTION (MCB)

A generator as energy producing machine installed should take protection against the installation that is to be connected, regardless of the configuration thereof, thus isolating the equipment from possible anomalies.
So we offer magnetothermics and spreads, added to the protection offered by the control board itself.

Conmutación del grupo electrógeno.

COMMUTATION

Indispensable for groups aimed at emergency service, the switchboard provides the operator to launch the boot order to the group to a network failure, and switches the input supply, returning to its natural state after reactivation of the mains.
Made with motorized equipment with manual option and display of electrical parameters, moves over the use of the old systems of contactors.

Protección del grupo electrógeno. Magnetotérmico.

COMMUNICATION

With the optional add-on communications, you can control the generator remotely from a PC, tablet or smartphone, thus accessing to the control of electrical parameters such as alarm notification or testing.

Protección del grupo electrógeno. Magnetotérmico.

SOUNDPROOFING

Perfect both to minimize noise, to their preparation for being outdoors without any additional protection or enclosure.

CUSTOMIZED


By having own design and manufacturing, it allows us to tailor our generating the specific needs of each client group. Therefore if you need a particular feature on a generator, we have the ability to add that feature. We recommend you request a quote if you want to adapt any model to your needs or need more information about a particular model.Request a quote / information.

WARRANTY


The generator is tested at the factory before delivery. Testing voltage, frequency and load are performed, as well as the proper functioning of alarms engine oil temperature and its effect on stop. For carrying a panel F.T.R. (automatic start failure) will be checked by simulating this situation.

LEGISLATION


Our groups have marked "CE" and each comes with the corresponding Declaration of Conformity, which covers the following directives and norms:

  • 2006/42/CE, on the safety of the machines.
  • 2005/88/CE, on noise in the environment by equipment for outdoor use emissions.
  • 2004/108/CE, on electromagnetic compatibility.
  • 2006/88/CE, on the emission of gaseous and particulate pollutants.
  • EN61326/2006 ,on electromagnetic compatibility testing.
  • EN12601-1:2010, on electrical safety tests in the electrical panel.
  • EN12601:2010, on electrical safety tests defined by generator
  • ISO 8532- ISO 3046, on power generator, with barometric reference 100 kPa, 25 ° C and 30% relative humidity.

Download

Reviews

No customer reviews for the moment.

Write a review

GENERATOR DIESEL TECNICS

GENERATOR DIESEL TECNICS

Generators Grupos electrógenos de la serie TKF y TYD series, equipped with an TECNICS engine of 1500 RPM and a frequency of 50 Hz, has a power range which comprises of 12 to 550 Kva, cooled by water.

Available in the following versions:

  • Open
  • Soundproof

Models available with Diesel engine.